Oct 26th, 2025
Granite River Labs Inc. (GRL) is pleased to announce the software release for the USB
Power Delivery and USB Type-C® Tester and Analyzer.
C2-EPR USB Power Delivery and USB Type-C® Tester and Analyzer software & firmware versions:
Software version : 1.6.39.0
Firmware version : 1.3.42
Eload Firmware version : 1.5
PPS Firmware version : 4.0
Key updates:
- Support added for USB PD CTS Q4 2025.
- Support added for Type C Functional tests 0.91.
- Support added for VIF Tool v3.14.0.0
- Compliance updated to support USB PD Specification 3.2, Version 1.1.
Note: Effective January 2025, the GRL USB Power Delivery and USB Type-C™ Test Software will exclusively support the GRL-USB-PD-C2-EPR hardware. As a result of updated specification requirements, the GRL-USB-PD-C2 hardware will no longer receive software updates. Users can continue to operate the GRL-USB-PD-C2 hardware with the GRL USB Power Delivery and USB Type-C™ Test Software version SW v1.6.28.0, which remains available for download at link. For assistance with upgrading your GRL-USB-PD-C2 to the latest GRL-USB-PD-C2-EPR hardware, please contact GRL support.
Issues addressed:
- COMMON.CHECK.PD.11 - Improved validation to handle the Bit0...6 (Source rated PDP) in Source Capability Extended Message.
- TD.4.10.6 - Enhanced configuration to handle the Discover Identity message during the ALT mode sequence.
- TEST.PD.PS.SNK.1 - Adjusted validation to ensure the proper current validation based on the previous contracted current.
- TD.4.2.5 - Improved validation to handle the VBUS voltage measurement during Attach condition.
- TEST.PD.VDM.SNK.1 - Enhanced validation to handle the response for Discover SVID if SVID fixed SOP is set to No.
- TEST.PD.EPR.SNK3.1 - Improved validation to handle the Message ID of SOP’ message during the EPR enter flow.
- TC.10.7.2 - Adjusted configuration to handle the Structure VDM version for Discover Identity message.
- TD.4.3.1 - Enhanced validation to handle the disable state during the voltage drop sequence.
Known issues:
Software generated VIF is not compatible with the USB-IF VIF generator tool.
Instructions to update the software:
-
Download the software from here
-
Run the installer and follow the instructions on the screen.
-
After installing the software, update the firmware of your GRL-USB-PD-C2/C2-EPR before running any tests.
-
If you experience any issues with the installation procedure, please submit a ticket for assistance.
Please see “ReadMe” for additional mandatory steps required for using the system.
USB Type-C®, USB-C® and USB 2.0 Type-C™ are trademarks of USB Implementers Forum
About Granite River Labs (GRL)
The world’s leading Engineering Services and Test Automation Solutions firm for connectivity and charging, GRL helps engineers solve tough design and validation challenges. GRL began in 2010 with a vision to provide affordable test services to help hardware developers implement digital interface technologies as they become faster, more complex, and more challenging to test. Today, GRL has worked with hundreds of companies supporting the adoption of new and emerging technologies from our worldwide test facilities and R&D centers.
MEDIA CONTACT:
Nikhil Acharya
Technology and Solutions Product Manager
Email: support@graniteriverlabs.com
Have a question or feedback? Write to us here.