GRL-PD-C2/C2-EPR Software Release Version 1.6.31.0

April 28th, 2025

Granite River Labs Inc. (GRL) is pleased to announce the software release for the USB
Power Delivery and USB Type-C® Tester and Analyzer.

C2-EPR USB Power Delivery and USB Type-C® Tester and Analyzer software & firmware versions:
Software version                       : 1.6.31.0
Firmware version                      : 1.2.85
Eload Firmware version           : 1.5
PPS Firmware version             : 4.0

Key updates:

  1. Support added for USB PD CTS Q1 2025.
  2. Support added for loading VIF files generated using VIF Tool v3.11.0.0.
  3. Solution updated to support USB PD Specification 3.2, Version 1.0.


Note:
Effective January 2025, the GRL USB Power Delivery and USB Type-C™ Test Software will exclusively support the GRL-USB-PD-C2-EPR hardware. As a result of updated specification requirements, the GRL-USB-PD-C2 hardware will no longer receive software updates. Users can continue to operate the GRL-USB-PD-C2 hardware with the GRL USB Power Delivery and USB Type-C™ Test Software version SW v1.6.28.0, which remains available for download at link. For assistance with upgrading your GRL-USB-PD-C2 to the latest GRL-USB-PD-C2-EPR hardware, please contact GRL support.


Issues addressed:

    • TEST.PD.PS.EPR.SRC3.2 - Enhanced validation for SPR AVS PDO request sequence.
    • TEST.PD.PS.SRC.4 - Improved handling of capability mismatch bit in the request message.
    • TD.4.6.3 - Updated to handle the VBUS voltage measurement for Vsafe0V condition.
    • TEST.PD.PS.SRC.1 - Updated to handle the tSrcTransition timer during PDO transition.
    • TEST.PD.EPR.SNK3.1 - Updated to handle the PD contract after the Exit Mode sequence.
    • TD.4.7.3 - Updated to handle the Attach SRC state transition.
    • TEST.PD.PS.SNK.1 - Updated to handle the current drawn for 5 seconds.
    • TEST.PD.PROT.SNK.10 - Updated to handle the response message for DR Swap sequence.
    • COMMON.CHECK.PD.14 - Updated to handle the tSrcRecover timer during Hard Reset sequence. 


Known issues:

Software generated VIF is not compatible with the USB-IF VIF generator tool.

 

Instructions to update the software:

Please see “ReadMe” for additional mandatory steps required for using the system.

USB Type-C®, USB-C® and USB 2.0 Type-C™ are trademarks of USB Implementers Forum

 

About Granite River Labs (GRL)

The world’s leading Engineering Services and Test Automation Solutions firm for connectivity and charging, GRL helps engineers solve tough design and validation challenges. GRL began in 2010 with a vision to provide affordable test services to help hardware developers implement digital interface technologies as they become faster, more complex, and more challenging to test. Today, GRL has worked with hundreds of companies supporting the adoption of new and emerging technologies from our worldwide test facilities and R&D centers.   


MEDIA CONTACT:

Nikhil Acharya
Technology and Solutions Product Manager
Email: support@graniteriverlabs.com


Have a question or feedback? Write to us here.